Benchtop Conductivity Meter LBCM-A14

Benchtop Conductivity Meter LBCM-A14

https://laboscience.com/ | info@laboscience.com

Benchtop Conductivity Meter LBCM-A14

Benchtop Conductivity Meter LBCM-A14 with 1 to 3 points push button conductivity calibration, automatically recognizes calibration standards. With setup menu, it does setting of 6 parameters calibration points, temperature units and others. Large LCD display shows settings and measurement values. Temperature calibration by manual method improves the accuracy of conductivity meter.

Specifications:

Conductivity Mode
Conductivity measurement rangeConductivity accuracyConductivity resolutionConductivity calibration pointsConductivity calibration solutions
0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm±1% F.S.0.001, 0.01, 0.1, 11 to 3 points10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
TDS Mode
TDS measurement RangeTDS AccuracyTDS FactorTDS Calibration points
0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)± 1 % F.S.0.01 to 1.00 (default 0.5)3 points
Temperature Mode
Temperature rangeTemperature accuracyTemperature resolutionTemperature calibration pointsTemperature Compensation Range and ModeTemperature coefficient
0 to 105°C, 32 to 221°F±1°C0.1°C, 0.1°F1 pointManual or Automatic, 0 to 100°C , 32 to 212°F0.0 to 10.0 % per °C
Cell constant K=0.1, 1, 10
Power requirements DC 9 V, using AC adapter, AC 220 V, 50 Hz
Dimension (L×W×H) 210 × 205 × 75 mm
Weight 1.5 kg

Features:

    •  Measures conductivity, TDS, Temperature of the liquids
    •   Automatic temperature compensation for accurate values over the entire range
    •   Selectable temperature units (°C or °F) for different application requirements
    •   Reset function automatically resumes all the setting back to factory default options
    •   Manual and automatic mode of temperature calibration
    •   Auto hold feature to lock, record and read stable measurement endpoint
    •   Stability indicator displays the status of current measurement
    •   Help message as an operational guide, with quick access to test parameters
    •   Conductivity/TDS Mode
    •   1 to 3 Conductivity push button calibration points
    •   3 TDS calibration points
    •   1 Temperature calibration point

Applications:

Used to test Conductivity, TDS values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose


Standard Accessories:

Accessories no. Name
1 Conductivity Electrode (range 0.01 to 20 mS/ cm)
2 Temperature Probe
3 Conductivity Calibration Standard Solutions
4 Electrode Holder
5 Power Adapter


Optional Accessories:

Accessories no. Name
1 Conductivity Electrode (K=0.1) suitable for measuring the low conductivity liquids ( <10µS/ cm) e.g. Pure water
2 Conductivity Electrode (K=10) suitable for measuring the high conductivity liquids (>20mS/ cm) e.g. Sea water


 
     
 

  

Laboscience