Benchtop Conductivity Meter LBCM-A14
Benchtop Conductivity Meter LBCM-A14 with 1 to 3 points push button conductivity calibration, automatically recognizes calibration standards. With setup menu, it does setting of 6 parameters calibration points, temperature units and others. Large LCD display shows settings and measurement values. Temperature calibration by manual method improves the accuracy of conductivity meter.
Specifications:
| Conductivity Mode |
| Conductivity measurement range | Conductivity accuracy | Conductivity resolution | Conductivity calibration points | Conductivity calibration solutions |
|---|
| 0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm | ±1% F.S. | 0.001, 0.01, 0.1, 1 | 1 to 3 points | 10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm | |
| TDS Mode |
| TDS measurement Range | TDS Accuracy | TDS Factor | TDS Calibration points |
|---|
| 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) | ± 1 % F.S. | 0.01 to 1.00 (default 0.5) | 3 points | |
| Temperature Mode |
| Temperature range | Temperature accuracy | Temperature resolution | Temperature calibration points | Temperature Compensation Range and Mode | Temperature coefficient |
|---|
| 0 to 105°C, 32 to 221°F | ±1°C | 0.1°C, 0.1°F | 1 point | Manual or Automatic, 0 to 100°C , 32 to 212°F | 0.0 to 10.0 % per °C | |
| Cell constant |
K=0.1, 1, 10 |
| Power requirements |
DC 9 V, using AC adapter, AC 220 V, 50 Hz |
| Dimension (L×W×H) |
210 × 205 × 75 mm |
| Weight |
1.5 kg |
Features:
- Measures conductivity, TDS, Temperature of the liquids
-
Automatic temperature compensation for accurate values over the entire range
-
Selectable temperature units (°C or °F) for different application requirements
-
Reset function automatically resumes all the setting back to factory default options
-
Manual and automatic mode of temperature calibration
-
Auto hold feature to lock, record and read stable measurement endpoint
-
Stability indicator displays the status of current measurement
-
Help message as an operational guide, with quick access to test parameters
-
Conductivity/TDS Mode
-
1 to 3 Conductivity push button calibration points
-
3 TDS calibration points
-
1 Temperature calibration point
Applications:
Used to test Conductivity, TDS values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose
|
Standard Accessories:
| Accessories no. |
Name |
| 1 |
Conductivity Electrode (range 0.01 to 20 mS/ cm) |
| 2 |
Temperature Probe |
| 3 |
Conductivity Calibration Standard Solutions |
| 4 |
Electrode Holder |
| 5 |
Power Adapter |
|
Optional Accessories:
| Accessories no. |
Name |
| 1 |
Conductivity Electrode (K=0.1) suitable for measuring the low conductivity liquids (
<10µS/ cm) e.g. Pure water
|
| 2 |
Conductivity Electrode (K=10) suitable for measuring the high conductivity liquids (>20mS/ cm) e.g. Sea water |
|