Water Soluble Acid and Alkali Tester LAAT-A10
Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Base Number Tester LAAT-A13
Volumetric analysis Titration condensation: 0.1 N;
Controlling accuracy: ≤ ± 0.02 ml
Automatic acid titration Titration condensation: 0.1 N;
Controlling accuracy: ≤ ± 0.1 pH
Automatic Bomb Calorimeter LABC-A10
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode The outer barrel temperature is constant
Temperature resolution 0.0001°C
Automatic Bomb Calorimeter LABC-A11
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Temperature resolution 0.0001°C
Automatic Bomb Calorimeter LABC-B10
Calorimeter type Isoperibol
Oxygen filling Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume 250 ml
Analysis time < 8 min full test process: <10 min
Bomb washing Manual
Automatic Bomb Calorimeter LABC-B11
Calorimeter type Isoperibol
Oxygen filling Semi-automatic
Bomb volume 282 ml
Analysis time 15 to 25 min
Bomb washing Manual
Ash Content Tester LACT-A10
Electric Muffle Furnace Controlled temperatureTemperature rising time of empty chamberFurnace temperature uniformityInternal dimensionExternal dimensionPower consumptionPower supplyNet weight
775 ±25 ℃
≤ 50 min
≤ 15℃
200 × 120 × 80 mm
490 × 490 × 450 mm
2.5 kW
AC 220V ±10%, 50 Hz
35 kg
Temperature controller Maximum control temperatureDimensionPower consumptionPower supplyNet weight
1200 ℃
500 × 300 × 235 mm
5000 W
AC 220±10% V, 50Hz
5 kg
Electric heating plate Heating powerTemperatureDiameter of heating plateDimensionPower consumptionPower supply
(1 to 6) grades, continuously adjustable
400℃
Φ 180 mm
280 × 250 × 90 mm
2000 W
AC 220±10%V, 50Hz
Automatic Distillation Apparatus LADA-A10
Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Refrigeration temperature 0 to 60℃
Automatic Dielectric Tester LADT-A10
Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01
Breakdown sensitivity < 0.1 kV
Waveform distortion ≤ 1 %
Aniline Point Tester LAPT-A10
Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W
Interior Dimension 360 × 250 × 545 mm
Exterior Dimension 370 × 320 × 630 mm
PMCC Flash Point Tester LCFP-A10
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Temperature range 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device 0.8 mm
Automatic PMCC Flash Point Tester LCFP-A11
Ambient temperature 10 °C ~ 40 °C
Relative humidity ≤ 80 %
Automatic PMCC Flash Point Tester LCFP-A13
Ambient temperature 10 °C ~ 40 ℃
Relative humidity ≤ 80 %
Ignition Mode electron igniter / gas flame
Temperature range Room Temperature ~ 300 ℃
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Timing range 1 s to 9 min 59 s
Temperature controlling range Room temperature to 99.9 °C
Temperature controlling accuracy ± 1 °C
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Temperature controlling range Room temperature to 99.9 °C
Temperature controlling accuracy ± 1 °C
Density Tester LDMT-A10
Cubage of bath Ф300 × 380 mm
Temperature controlling range 0 °C ~ 100 °C
Temperature controlling accuracy ± 0.2 °C
Temperature sensor Industrial platinum resistance, Pt100
Thermometer Total immersion mercury thermometer
Dropping Point Tester (Oil Bath) LDPT-A10
Beaker quantity 600 ml
Ambient temperature (-10) °C ~ 40 °C
Relative humidity ≤ 85 %
Thermometer Measurement range (-5) °C ~ 300 °C
Thermometer Scale division 1 °C
Dropping Point Tester (Air bath) LDPT-A11
Ambient temperature ≤ 35 ℃
Relative humidity ≤ 85 %
Existent Gum Tester LEGT- B30
Bath type Oil bath
Bath capacity 5000 ml ± 50 ml
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Temperature controlling range RT to 250 °C
Engler Viscometer LEV-A10
Graduated Flask 200 ± 0.2 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.2 °C
Engler Viscometer LEV-A11
Graduated Flask 100 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.1 °C
Engler Viscometer LEV-B10
Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature 10 °C ~ 40 °C
Temperature Controlling Accuracy ± 0.1 °C
Foaming Characteristics Tester LFCT-A10
Temperature Range Ambient to 100°C
Temperature Precision ± 0.1°C
Air Flow 94 mL ± 5 mL/min, with flowmeters
Timing Unit 0 to 99 min 59 s, resolution 1 s
Control System Single chip microcontroller
Carbon Residue Tester (Ramsbottom) LRCT-B20
Coking furnace Metal furnace
Heating mode Electric heating
Test unit 5 units
Temperature range Ambient to 550°C
Temperature precision ≤ ± 5℃
Constant Temperature Needle Penetration Tester LTNP-A10
Measuring range 0 to 700 taper degree (digital display table 0-70 mm)
Timing device Timing error is less than ±0.1 s
 Resolution 0.01 mm
Needle insertion accuracy ±1 cone insertion degree
Temperature range 10 to 50˚C
Coulometric Karl Fischer Titrator LWT-A31
Maximum current 400 mA
Measurement range 3 µg to 9999.9 µg
Resolution 0.1 µg
Precision 1 ± 2 µg (3µg H2O to 20µg H2O)
Precision 2 ± 3 µg (20µg H2O to 100µg H2O)