Gas Chromatography LGC-B11
Gas Chromatography LGC-B11 is a benchtop unit with advanced flow controller (AFC) technology. System has digital control mode and polar capillary columns to separate polar analytes. GC oven is capable of 9 temperature program ramps and hold steps, and features rapid cooling: 250 °C to 50 °C < 10 minutes. Accurate flow rate control via AFC has higher level repeatability of retention time and peak area, enabling specific level of analysis by means of dual FID detectors.
Specifications:
| Oven |
| Maximum capacity | Temperature range | Temperature accuracy | Temperature program | Program total time | Maximum temperature heating rate | Maximum cooling rate |
|---|
| 22 L | RT + 5 ℃ to 400 ℃ | ± 0.1 ℃ | 9-phase/ 10 platform | 9999.9 min | 0.1 to 60 ℃/ min | ˂ 10 mins (250 to 50 ℃) | |
| Sample injector |
| Temperature range | Temperature control | Injector type | Maximum sample inlet | Carrier gas flow type | Pre column pressure range | Pre column pressure accuracy | Mobile phase flow range |
|---|
| RT+ 7 ℃ to 420 ℃ | Automatic | Column or split | 3 pcs | Constant pressure | 0 to 400 kPa | 0.1 kPa | H2: 0 to 200 ml/min, N2: 0 to 150 ml/min | |
| Detector |
| Temperature range | Maximum installation | Flame ignition mode | Flame Ionization Detector (FID) |
|---|
| RT + 7 ℃ to 420 ℃ | Dual detector | Automatic | Logarithmic amplifier
High voltage switch control
Baseline signal display
Ignition coil control
Detection limit: ≤3 ×10 to 12 g/s
(Sample: n-hexadecane)
Baseline noise: ≤ 5 × 10 - 14 A
Baseline draft: ≤ 6 × 10 -13 A
Dynamic range: 10 7
RSD: ≤ 3 % | |
| Power supply |
AC 220 V ± 22 V, 50 Hz ± 0.5 Hz, 3000 W |
| Packing dimension |
1020 × 660 × 740 mm |
| Gross Weight |
82 kg |
| Net weight |
70 kg |
Features:
- 7-inch LCD display specifies temperature, gas flow and heating curve
-
H2 and N2 mobile gas phase with AFC and constant pressure gas flow type
-
Equipped with capillary analysis system and capillary split sampler
-
Injection system incorporates diaphragm cleaning, split flow and auxiliary gas adjustment
-
Standard unit for high-speed analysis with polar capillary column
-
PEG-20M and FFAP stationary phase polar capillary columns can be coupled
-
Dual FID detector with automatic flame ignition and baseline signal display
-
Self-diagnostic and automatic fault recognition function
-
Multi-core and 32-bit embedded hardware system ensures the reliable operation
-
Equipped with chromatography workstation software to process data
-
Memory function can store 20 sample test data
-
RS232 interface and LAN port
Applications:
Suitable for analysis of trace toxic compounds, monitoring and research in environmental protection, atmosphere and water source pollution. It is widely used for petrol-chemistry, environmental protection, epidemic prevention, pharmacology and scientific research.
|
Standard Accessories:
| Accessories no |
Accessories name |
| 1. |
FID detector system |
| 2. |
Capillary injection system |
| 3. |
Chromatography workstation software |
|
Optional Accessories:
| Accessories no |
Accessories name |
| 1 |
Polar capillary columns PEG-20M
Stationary phase: 30 m × 0.32 mm
injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
|
| 2 |
Polar capillary columns FFAP
Stationary phase: 30 m × 0.32 mm
Injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
|
| 3 |
Syringe 1 ul |
| 4 |
Syringe 5 ul |
|